What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A 1 INCH CRACK AT STATION 359 STRINGER 14L IN TIE CHANNEL TO STRINGER. INSTALLED NEW CHANNEL PER EA 65686. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A 1 INCH CRACK AT STATION 359 STRINGER 14L IN TIE CHANNEL TO STRINGER. INSTALLED NEW CHANNEL PER EA 65686. (M)