What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND SEVERAL .5 INCH BY .5 INCH CORROSION AREAS AT SCREW HOLES FLOORBEAM STATION 344, RBL 8 - RBL 56 UPPER CHORD. CORROSION LEVEL 1. REPLACED T-CAP PER SRM 53-15-01A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND SEVERAL .5 INCH BY .5 INCH CORROSION AREAS AT SCREW HOLES FLOORBEAM STATION 344, RBL 8 - RBL 56 UPPER CHORD. CORROSION LEVEL 1. REPLACED T-CAP PER SRM 53-15-01A. (M)