What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 2 CRACKS, 1 AT 1.25 INCH LONG AND 1 AT .0675 INCH LONG EMANATING FROM RIVETS IN FUS AT LOWER AFT CORNER OF FORWARD SERVICE DOOR CUTOUT SKIN. INSTALLED DOUBLER PER SRM 53-10-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 2 CRACKS, 1 AT 1.25 INCH LONG AND 1 AT .0675 INCH LONG EMANATING FROM RIVETS IN FUS AT LOWER AFT CORNER OF FORWARD SERVICE DOOR CUTOUT SKIN. INSTALLED DOUBLER PER SRM 53-10-01. (M)