What was found
CLT - DURING Q-1/CX-6 CHECK VISUAL INSPECTION, FUOND A .25 INCH CRACK AT STATION 706, STRINGER 11L AFT SIDE OF FRAME ATTACH ANGLE. FABRICATED NEW ANGLE PER DRAWING 66-23574. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1/CX-6 CHECK VISUAL INSPECTION, FUOND A .25 INCH CRACK AT STATION 706, STRINGER 11L AFT SIDE OF FRAME ATTACH ANGLE. FABRICATED NEW ANGLE PER DRAWING 66-23574. (M)