What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A CORRODED AREA 1 INCH BY 8 INCH AT FLOORBEAM BS 986.5, LBL 44 TO RBL 44 BEAM. CORROSION LEVEL 2, CORROSION TASK NR C53-107-02. REPLACED CORRODED AREA PER SRM 53-00-51. (M)