What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 1 INCH AREA OF CORROSION STATION 344 FLOORBEAM UPPER FLANGE LBL 12 TO RBL 10. CORROSION LEVEL 1. NEW SECTION SPLICED IN PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 1 INCH AREA OF CORROSION STATION 344 FLOORBEAM UPPER FLANGE LBL 12 TO RBL 10. CORROSION LEVEL 1. NEW SECTION SPLICED IN PER SRM 53-10-51. (M)