As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CLT - DURING A DROP-IN VISUAL INSPECTINO, FOUND A 1 INCH AREA OF CORROSION AT NUTPLATE HOLES ON UPPER CHORD FLOORBEAM T-CAP STATION 986.5 BETWEEN LBL 45 AND RBL 45. CORROSION LEVEL 1. INSTALLED NEW SECTION OF T-CAP PER SRM 53-00-51. (M)