What was found
CLT - DURIGN Q-1 CHECK VISUAL INSPECTION, FOUND A CORRODED AREA 2 INCH BY 32 INCH AT LBL 55 STATION 312 TO 344 FLOORBEAM LEFT Z ANGLE. CORROSION LEVEL 2, CORROSION TASK NR C53-107-01. REPLACED WITH IDENTICAL PART PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURIGN Q-1 CHECK VISUAL INSPECTION, FOUND A CORRODED AREA 2 INCH BY 32 INCH AT LBL 55 STATION 312 TO 344 FLOORBEAM LEFT Z ANGLE. CORROSION LEVEL 2, CORROSION TASK NR C53-107-01. REPLACED WITH IDENTICAL PART PER SRM 51-10-02. (M)