CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CORROSION AROUND 7.25 INCH AT FLOORBOARD FASTENERS HOLES FLOORBEAM 312 LBL 11 TO RBL 11. CORROSION LEVEL 2. INSTALLED 'T' CAP AND DOUBLER EPR SRM 53-10-51. (M)