What was found
PIT - DURING Q2 CHECK, FOUND .50 INCH CRACK AT FRAME ATTACH POINT AT STA 160 LONGERON 3 LEFT. INSTALLED SPLICE PER SRM 53-02, FIG 18. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q2 CHECK, FOUND .50 INCH CRACK AT FRAME ATTACH POINT AT STA 160 LONGERON 3 LEFT. INSTALLED SPLICE PER SRM 53-02, FIG 18. (X)