What was found
PIT - DURING Q2 CHECK, FOUND 1 INCH CRACK AT FRAME STA 160 LONGERON 2 LEFT. INSTALLED SPLICES PER SRM 53-02 FIG 18. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q2 CHECK, FOUND 1 INCH CRACK AT FRAME STA 160 LONGERON 2 LEFT. INSTALLED SPLICES PER SRM 53-02 FIG 18. (X)