As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A CORRODED AREA 1 INCH BY 2 INCH AT STATION 847 BETWEEN STRINGER 24R AND 25R FRAME. CORROSION LEVEL 1. CORROSION TASK NR C53-208-01. INSTALLED DOUBLER AND FILLER PER SRM 53-00-07 FIG 201 AND EA 65717. (M)