What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .500 INCH WIDE AREA OF CORROSION AT STATION 360, CORROSION LEVEL 2. INSTALLED STRAP PER SRM 53-00-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .500 INCH WIDE AREA OF CORROSION AT STATION 360, CORROSION LEVEL 2. INSTALLED STRAP PER SRM 53-00-51. (M)