What was found
CLT - DURING WALK AROUND VISUAL INSPECTION, FOUND A .875 INCH CRACK SEC 46 FUSELAGE SKIN JUST BELOW STRINGER 23L, BS 727D PLUS 2 INCHES. CUTOUT CRACKED AREA AND INSTALLED FILLER AND DOUBLER PER TR 53-60-003. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING WALK AROUND VISUAL INSPECTION, FOUND A .875 INCH CRACK SEC 46 FUSELAGE SKIN JUST BELOW STRINGER 23L, BS 727D PLUS 2 INCHES. CUTOUT CRACKED AREA AND INSTALLED FILLER AND DOUBLER PER TR 53-60-003. (M)