What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH CRACK AT STATION 178, 5 INCHES BELOW FLOOR AT STIFFENER 3 SKIN. INSTALLED DOUBLER PER TR 53-10-07 REV A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH CRACK AT STATION 178, 5 INCHES BELOW FLOOR AT STIFFENER 3 SKIN. INSTALLED DOUBLER PER TR 53-10-07 REV A. (M)