What was found
PIT - DURING RON, FOUND 1 INCH LONG CRACK IN FUSELAGE SKIN AT FORWARD AIRSTAIR DOOR CUT OUT LOWER AFT CORNER AT STATION 200. INSTALLED EXTERNAL DOUBLERS PER SRM 53-05 FIG 57A. (M)