What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK THROUGH RIVET HOLE BS 847, STRINGER 9R BELT FRAME. INSTALLED DOUBLER PER TR 53-10-14. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK THROUGH RIVET HOLE BS 847, STRINGER 9R BELT FRAME. INSTALLED DOUBLER PER TR 53-10-14. (M)