What was found
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .250 INCH CRACKS IN 2 PLACES STATION 178 WEB A AND WEB B, LBL 1 AND RBL 1 SKIN. INSTALLED DOUBLER PER SRM 53-10-08. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .250 INCH CRACKS IN 2 PLACES STATION 178 WEB A AND WEB B, LBL 1 AND RBL 1 SKIN. INSTALLED DOUBLER PER SRM 53-10-08. (M)