What was found
PIT - DURING RON VISIT, FOUND 1.125 INCH CRACK IN T-FITTING (W/O JOGGLE) AT BOTTOM END OF T-FITTING AFT SIDE APBH BL 1027L. STOP DRILLED CRACK PER CD. REINSTALLED BLIND FASTENERS PER CD 53F00703. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING RON VISIT, FOUND 1.125 INCH CRACK IN T-FITTING (W/O JOGGLE) AT BOTTOM END OF T-FITTING AFT SIDE APBH BL 1027L. STOP DRILLED CRACK PER CD. REINSTALLED BLIND FASTENERS PER CD 53F00703. (M)