What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 827 BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED FRAME REPAIR PER EA 66032. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK AT BS 827 BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED FRAME REPAIR PER EA 66032. (M)