What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK AT BS 867 BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED DOUBLER PER TR 53-10-14 AND EA 66037. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK AT BS 867 BETWEEN STRINGER 8L AND 9L FRAME. INSTALLED DOUBLER PER TR 53-10-14 AND EA 66037. (M)