What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND ONE INCH AREA OF CORROSION TOP SURFACE AROUND CLIPNUT HOLE STATION 967 RBL 30 FLOORBEAM. CORROSION LEVEL 2. INSTALLED FILLER AND REPAIR ANGLES PER SRM 53-30-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND ONE INCH AREA OF CORROSION TOP SURFACE AROUND CLIPNUT HOLE STATION 967 RBL 30 FLOORBEAM. CORROSION LEVEL 2. INSTALLED FILLER AND REPAIR ANGLES PER SRM 53-30-51. (M)