What was found
CLT - DURNG Q-6 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY4 INCH AREA OF CORROSION AT STATION 500B STRINGER 27R SKIN. CORROSION LEVEL 2. CORROSION TASK NR C53-202-01. INSTALLED DOUBLER PER SRM 53-30-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURNG Q-6 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY4 INCH AREA OF CORROSION AT STATION 500B STRINGER 27R SKIN. CORROSION LEVEL 2. CORROSION TASK NR C53-202-01. INSTALLED DOUBLER PER SRM 53-30-3. (M)