What was found
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION 20 INCH BY 2 FT AT STATION 344, LBL 10 RBL 10 T-CAP. CORROSION LEVEL 2. FABRICATED NEW T-CAP PER TR 53-10-13. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION 20 INCH BY 2 FT AT STATION 344, LBL 10 RBL 10 T-CAP. CORROSION LEVEL 2. FABRICATED NEW T-CAP PER TR 53-10-13. (M)