What was found
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 1 INCH AT BS 1016, STRINGER 20R TIE FITTING. CORROSION LEVEL 1. REMOVED CORROSION AND PRIMED PER SRM 51-10-06. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 1 INCH AT BS 1016, STRINGER 20R TIE FITTING. CORROSION LEVEL 1. REMOVED CORROSION AND PRIMED PER SRM 51-10-06. (M)