What was found
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND TWO 1.125 INCH CRACKS AT STRINGER 4L STATION 685 TIE CLIP. INSTALLED TIE CLIP PER SRM 51-10-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND TWO 1.125 INCH CRACKS AT STRINGER 4L STATION 685 TIE CLIP. INSTALLED TIE CLIP PER SRM 51-10-01. (M)