What was found
TPA - DURING CX-5 CHECK VISUAL AND EDDY CURRENT INSPECTION, FOUND MINOR CORROSION 4 INCH BY 6 INCH BOTTOM KEEL BEAM STATION 727 STRINGER 26L. CORROSION LEVEL 1. INSTALLED DOUBLER PER SRM 53-30-3 FIG 28. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TPA - DURING CX-5 CHECK VISUAL AND EDDY CURRENT INSPECTION, FOUND MINOR CORROSION 4 INCH BY 6 INCH BOTTOM KEEL BEAM STATION 727 STRINGER 26L. CORROSION LEVEL 1. INSTALLED DOUBLER PER SRM 53-30-3 FIG 28. (M)