What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 1.5 INCH CRACK STATION 344, STRINGER 11R TIE CLIP. REPLACED TIE CLIP PER SRM 51-10-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 1.5 INCH CRACK STATION 344, STRINGER 11R TIE CLIP. REPLACED TIE CLIP PER SRM 51-10-01. (M)