PIT - DURING Q-1 CHECK, FOUND .125 - .25 INCH CRACK IN FRAME STATION 500A BETWEEN STRINGER 8, 9 LEFT. DOUBLER INSTALLED PER EA NR 53440. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK, FOUND .125 - .25 INCH CRACK IN FRAME STATION 500A BETWEEN STRINGER 8, 9 LEFT. DOUBLER INSTALLED PER EA NR 53440. (M)