What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 2 INCH CRACK STATION 727, BL 0, WL 206 FITTING. INSTALLED REPLACEMENT FITTING AND MOD PER EO 5394G176. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 2 INCH CRACK STATION 727, BL 0, WL 206 FITTING. INSTALLED REPLACEMENT FITTING AND MOD PER EO 5394G176. (M)