What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 2 INCH CRACK STATION 578, STRINGER 5R TIE CLIP. INSTALLED NEW TIE CLIP PR EO53936227. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 2 INCH CRACK STATION 578, STRINGER 5R TIE CLIP. INSTALLED NEW TIE CLIP PR EO53936227. (M)