What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 2 INCH AREA OF CORROSION BS 993, STRINGER 20R, CORROSION LEVEL 1. SPLICED IN NEW SECTION PER SRM 53-10-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 2 INCH AREA OF CORROSION BS 993, STRINGER 20R, CORROSION LEVEL 1. SPLICED IN NEW SECTION PER SRM 53-10-03. (M)