What was found
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 6 INCH BY 1.5 INCH AREA OF CORROSION ON FRAME STATION 927 BETWEEN STRINGER 27L AND STRINGER 7R. CORROSION LEVEL 2. INSTALLED REPAIR DOUBLER PER SRM 53-00-07 AND SRM 51-40-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 6 INCH BY 1.5 INCH AREA OF CORROSION ON FRAME STATION 927 BETWEEN STRINGER 27L AND STRINGER 7R. CORROSION LEVEL 2. INSTALLED REPAIR DOUBLER PER SRM 53-00-07 AND SRM 51-40-01. (M)