What was found
PIT - DURNG Q-6, C-6 CHECK, FOUND 3 INCH BY 57 INCH CORRODED AREA AT BEAM, DOUBLER, PAN AT STATION 636 TO 693 MID CARGO DOOR JAMB LOWER EDGE. CORROSION LEVEL 1. CORROSION TASK NR C51-53300. SPLICED IN NEW PAN SECTION PER SRM 53-05 FIG 63. (M)