As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EN ROUTE FROM LAS TO PHL, CREW RECEIVED AN EICAS MESSAGE FOR STANDBY INVERTER AND THE FILGHT ATTENDANT REPORTED AN ELECTRICAL ODOR IN THE CABIN. FLIGHT DIVERTED TO MCI AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE CONFIRMED STATIC INVERTER WAS SOURCE OF ODOR IN THE CABIN. REMOVED AND REPLACED STATIC INVERTER PER MM 24-33-03. CLEARED EICAS STATUS MESSAGE. OPERATIONAL CHECK GOOD. (M)