What was found
PIT - FLT 781 - CREW NOTED ELECTRICAL SMELL IN AFT GALLEY. (CIRCUIT BREAKER HAD TRIPPED.) MAINTENANCE FOUND THE CABLE ASSEMBLY FOR HEATED MEAL CART A201 ARCING AND REPLACED IT. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FLT 781 - CREW NOTED ELECTRICAL SMELL IN AFT GALLEY. (CIRCUIT BREAKER HAD TRIPPED.) MAINTENANCE FOUND THE CABLE ASSEMBLY FOR HEATED MEAL CART A201 ARCING AND REPLACED IT. (X)