What was found
CLT - THE FORWARD EMERGENCY POWER SUPPLY UNIT INDICATED AN EXTERNAL LIGHT FAULT. MAINTENANCE REPLACED AN EMERGENCY POWER SUPPLY UNIT, HOWEVER, THE EXTERNAL LIGHT FAULT CONTINUED. THE FORWARD ESCAPE SLIDES WERE THEN REPLACED. SYSTEM OPERATIONALLY CHECKED OK. SUBSEQUENT REPAIR TO THE SLIDE, S/N 0A3629, WAS THE REPLACEMENT OF THE LAMP HARNESS'. (M)