What was found
ALB - MAINTENANCE FOUND THE FOLLOWING EMERGENCY LIGHTS INOPERATIVE, CENTER AISLE CEILING EXIT SIGN, LEFT OVERWING EXIT SIGN, LEFT SIDEWALL EXIT SIGN AT ROW 10 LEFT, AISLE LIGHTS ON SIDE OF SEATS 6 THROUGH 9 AND BULLNOSE EVACUATION LIGHT AT ROW 7 RIGHT. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK (P/N 2013-1ALP) AND CHARGER ASSEMBLY. OPERATIONAL CHECK GOOD. (M)