What was found
DURING WEEKLY CHECK, BDL MAINTENANCE REPORTED THE SEAT MOUNTED EMERGENCY LIGHTS ON SEAT ROWS 3, 4 AND 5, LEFT SIDE, INOPERATIVE. BDL MAINTENANCE FOUND A BROKEN GROUND WIRE FROM SEAT 2, LEFT SIDE TO SIDEWALL BENEATH CARPET. REPAIRED WIRE IN ASSOCIATION WITH B737 SPM 20-10-13. OPERATIONAL CHECK GOOD.