What was found
ORD - DURING OVERNIGHT CHECK, MAINTENANCE FOUND THE MAIN ENTRY DOOR EVACUATION SLIDE LIGHT INOP AND A FORWARD SECTION OF LOW LEVEL EMERGENCY LIGHTING INOP. MAINTENANCE RELAMPED THE EVACUATION SLIDE LIGHT (P/N 1619) AND REPAIRED BROKEN WIRE/SECURED LOOSE TRACK FOR LOW LEVEL EMERGENCY LIGHTS. OPERATIONAL CHECK GOOD. (M)