What was found
ATL - PILOT REPORTED THE EMERGENCY EXIT LIGHTS REMAIN ON IN THE ARMED POSITION. MAINTENANCE FOUND LOOSE HARDWARE AT THE FORWARD SERVICE DOOR EMERGENCY LIGHT POWER SUPPLY CAUSING A SHORT AND TRIPPING THE 'EMERG LIGHTS PWR' CIRCUIT BREAKER. SECURED HARDWARE AT THE FORWARD SERVICE DOOR EMERGENCY LIGHT POWER SUPPLY. RESET CIRCUIT BREAKER. EMERGENCY LIGHTS OPERATIONALLY CHECKED GOOD. (X)