What was found
LEFT FWD STORAGE CABINET, FWD INBD & OTBD FLOOR ANCHOR FITTINGS CORRODED. R & R BOTH FLOOR ANCHOR FITTINGS IAW CRJ700 SRM 51-42-21, 51-21-11, 51-25-06 & 51-25-16.