What was found
FLOOR SUPPORT CONNECTION SPLICE CORRODED AT FRAME 35 UNDER FLOORBOARD 252AF. BLENDED CORRODED AREA IAW SRM 53-23-10, AREA LESS THAN 10 PERCENT MATERIAL LOSS, FOUND TO BE WITH IN LIMITS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT CONNECTION SPLICE CORRODED AT FRAME 35 UNDER FLOORBOARD 252AF. BLENDED CORRODED AREA IAW SRM 53-23-10, AREA LESS THAN 10 PERCENT MATERIAL LOSS, FOUND TO BE WITH IN LIMITS.