What was found
CORROSION PIT ON ATTACHED FLANGE ON FRAME 364 BETWEEN STRINGER 27 & 26L. REPAIRED DAMAGED IAW REO 670-53-21-1115 DATED 2014-08-22 REV. SEE WORK ORDER 80242 WC 1082.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION PIT ON ATTACHED FLANGE ON FRAME 364 BETWEEN STRINGER 27 & 26L. REPAIRED DAMAGED IAW REO 670-53-21-1115 DATED 2014-08-22 REV. SEE WORK ORDER 80242 WC 1082.