What was found
FRAME AT FS 333.00, STRINGER 2R HAS A CRACK. R & R FRAME 333, BETWEEN STRINGER 0 - 8R IAW SRM 51-42-06, 51-42-21, 51-40-11, 51-25-06, 51-21-11, 51-25-16 & 51-32-54, AMM 51-21-01 & DWG SH 670-35625.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME AT FS 333.00, STRINGER 2R HAS A CRACK. R & R FRAME 333, BETWEEN STRINGER 0 - 8R IAW SRM 51-42-06, 51-42-21, 51-40-11, 51-25-06, 51-21-11, 51-25-16 & 51-32-54, AMM 51-21-01 & DWG SH 670-35625.