What was found
PASSENGER DOOR TOP STEP STRUCTURE DENTED ON TOP AFT CORNER BY GROUNDING STUD. REPAIRED TOP STEP STRUCTURE, BY GROUNDING STUD, BY FABRICATING REPAIR PART IAW SRM 52-11-04, 51-25-06, 51-25-16, AND 51-21-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PASSENGER DOOR TOP STEP STRUCTURE DENTED ON TOP AFT CORNER BY GROUNDING STUD. REPAIRED TOP STEP STRUCTURE, BY GROUNDING STUD, BY FABRICATING REPAIR PART IAW SRM 52-11-04, 51-25-06, 51-25-16, AND 51-21-11.