What was found
DENT LOCATED BETWEEN FRAMES 19-21 AND STRINGERS 11L AND 12L. CORRECTIVE ACTION: CUT OUT DAMAGED AREAS, FABRICATED REPAIR DOUBLER AND 2 EA FILLERS, AND INSTALLING REPAIR PARTS IAW EMB 145 SRM 51-75-00, SRM 51-40-02 AND ETD 2023-145-008516 REV.:/.