FS 279 FLOORBEAM CORRODED AT RBL 9 TO LBL 9 BEYOND SERVICEABLE LIMITS. INSTALLED NEW FLOORBEAM IAW SRM 51-42-13, 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 279 FLOORBEAM CORRODED AT RBL 9 TO LBL 9 BEYOND SERVICEABLE LIMITS. INSTALLED NEW FLOORBEAM IAW SRM 51-42-13, 51-42-21.