As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO BAY RT FLOOR SUPPORT BETWEEN FS 1030.0 AND 1051.0. REMOVED THE CORROSION, MAPPED AND MEASURED DAMAGE IAW SRM 51-21-06 AND REO 670-53-61-894. AN EDDIE CURRENT INSPECTION COMPLIED WITH IAW NDTM 51-20-006 NO REJECTABLE INDICATIONS, ALODINED, PRIMED, AND PAINTED IAW SRM 51-25-06.