FLOOR BEAM AT LBL 18 BETWEEN FRAMES 58 AND 61.5 CORRODED AROUND NUT PLATE HOLES. REMOVED AND REPLACED FLOOR BEAM AT LBL 18 BETWEEN FRAMES 58 AND 61.5 IAW EMB 145 SRM 51-40-02, SRM 51-20-03, AND SWPM 23-60-01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR BEAM AT LBL 18 BETWEEN FRAMES 58 AND 61.5 CORRODED AROUND NUT PLATE HOLES. REMOVED AND REPLACED FLOOR BEAM AT LBL 18 BETWEEN FRAMES 58 AND 61.5 IAW EMB 145 SRM 51-40-02, SRM 51-20-03, AND SWPM 23-60-01